Notitie
Voor toegang tot deze pagina is autorisatie vereist. U kunt proberen u aan te melden of de directory te wijzigen.
Voor toegang tot deze pagina is autorisatie vereist. U kunt proberen de mappen te wijzigen.
Specifies trace listeners that collect, store, and route messages and the level where a trace switch is set.
<configuration> Element
  <system.diagnostics> Element
<system.diagnostics> 
</system.diagnostics>
Attributes and Elements
The following sections describe attributes, child elements, and parent elements.
Attributes
None.
Child Elements
Element  | 
Description  | 
|---|---|
Specifies whether to display a message box when you call the Debug.Assert method; also specifies the name of the file to write messages to.  | 
|
Specifies the size of the global memory shared by performance counters.  | 
|
Contains listeners that any source or trace element can reference. Listeners identified as shared listeners can be added to sources or traces by name.  | 
|
Specifies trace sources that initiate tracing messages.  | 
|
Contains trace switches and the levels where the trace switches are set.  | 
|
Contains listeners that collect, store, and route tracing messages.  | 
Parent Elements
Element  | 
Description  | 
|---|---|
configuration  | 
The root element in every configuration file used by the common language runtime and .NET Framework applications.  | 
Example
The following example shows how to embed a trace switch and a trace listener inside the <system.diagnostics> element. The General trace switch is set to the TraceLevel.Error level. The trace listener myListener creates a file called MyListener.log and writes the output to the file.
Note
In the .NET Framework version 2.0, you can use text to specify the value for a switch. For example, you can specify true for a BooleanSwitch or use the text representing an enumeration value such as Error for a TraceSwitch. The line <add name="myTraceSwitch" value="Error" /> is equivalent to <add name="myTraceSwitch" value="1" />.
<configuration>
   <system.diagnostics>
      <switches>
         <add name="General" value="4" />
      </switches>
      <trace autoflush="true" indentsize="2">
         <listeners>
            <add name="myListener" type="System.Diagnostics.TextWriterTraceListener, System, Version=1.0.3300.0, Culture=neutral, PublicKeyToken=b77a5c561934e089" initializeData="MyListener.log" traceOutputOptions="ProcessId, LogicalOperationStack, Timestamp, ThreadId, Callstack, DateTime" />
         </listeners>
      </trace>
   </system.diagnostics>
</configuration>