Specifies the level where a trace switch is set.
<configuration>
<system.diagnostics>
<switches>
<add>
<add name="switch name"
value="value"/>
Required Attributes
| Attribute | Description |
|---|---|
| name | Specifies the name of the switch. The value of this attribute corresponds to the displayName parameter that is passed to switch constructor. |
| value | Specifies the level of the switch. |
Remarks
You can change the level of a trace switch by putting it in a configuration file. If the switch is a BooleanSwitch, you can turn it on and off. If the switch is a TraceSwitch, you can assign different levels to it to specify the types of trace or debug messages the application outputs.
Example
The following example shows how to use the <add> element to set the General trace switch to the TraceLevel.Error level, and enable the Data Boolean trace switch.
<configuration>
<system.diagnostics>
<switches>
<add name="General" value="4" />
<add name="Data" value="1" />
</switches>
</system.diagnostics>
</configuration>
Configuration File
This element can be used in the machine configuration file (Machine.config) and the application configuration file.