Edit

Share via


Remove-NetLbfoTeam

Removes the specified NIC team from the host.

Syntax

ByName

Remove-NetLbfoTeam
    [-Name] <String[]>
    [-CimSession <CimSession[]>]
    [-ThrottleLimit <Int32>]
    [-AsJob]
    [-PassThru]
    [-WhatIf]
    [-Confirm]
    [<CommonParameters>]

InputObject (cdxml)

Remove-NetLbfoTeam
    -InputObject <CimInstance[]>
    [-CimSession <CimSession[]>]
    [-ThrottleLimit <Int32>]
    [-AsJob]
    [-PassThru]
    [-WhatIf]
    [-Confirm]
    [<CommonParameters>]

Description

The Remove-NetLbfoTeam cmdlet removes the specified NIC team from the host. This cmdlet disconnects all associated team members and providers from the team. You can specify the team to remove by using either a team object retrieved by Get-NetLbfoTeam, or by specifying a team name.

You can use Remove-NetLbfoTeam to remove all NIC teams from the server.

You need administrator privileges to use Remove-NetLbfoTeam.

Examples

Example 1: Remove a team

PS C:\> Remove-NetLbfoTeam -Name Team1

This command removes the team named Team1.

Example 2: Remove a team using a team object

PS C:\> $team = Get-NetLbfoTeam -Name Team1
PS C:\> Remove-NetLbfoTeam -InputObject $team

This set of commands retrieves a team object into a variable $team using Get-NetLbfoTeam, and then passes the variable to Remove-NetLbfoTeam.

Example 3: Remove all teams from the server

PS C:\> Get-NetLbfoTeam | Remove-NetLbfoTeam

This command retrieves all the teams from the server using Get-NetLbfoTeam cmdlet and then sends all the retrieved teams to Remove-NetLbfoTeam which removes the teams.

Parameters

-AsJob

Runs the cmdlet as a background job. Use this parameter to run commands that take a long time to complete.

Parameter properties

Type:SwitchParameter
Default value:None
Supports wildcards:False
DontShow:False

Parameter sets

(All)
Position:Named
Mandatory:False
Value from pipeline:False
Value from pipeline by property name:False
Value from remaining arguments:False

-CimSession

Runs the cmdlet in a remote session or on a remote computer. Enter a computer name or a session object, such as the output of a New-CimSession or Get-CimSession cmdlet. The default is the current session on the local computer.

Parameter properties

Type:

CimSession[]

Default value:None
Supports wildcards:False
DontShow:False
Aliases:Session

Parameter sets

(All)
Position:Named
Mandatory:False
Value from pipeline:False
Value from pipeline by property name:False
Value from remaining arguments:False

-Confirm

Prompts you for confirmation before running the cmdlet.

Parameter properties

Type:SwitchParameter
Default value:False
Supports wildcards:False
DontShow:False
Aliases:cf

Parameter sets

(All)
Position:Named
Mandatory:False
Value from pipeline:False
Value from pipeline by property name:False
Value from remaining arguments:False

-InputObject

Specifies the input object that is used in a pipeline command.

Parameter properties

Type:

CimInstance[]

Default value:None
Supports wildcards:False
DontShow:False

Parameter sets

InputObject (cdxml)
Position:Named
Mandatory:True
Value from pipeline:True
Value from pipeline by property name:False
Value from remaining arguments:False

-Name

Specifies the name of the NIC team to remove.

Parameter properties

Type:

String[]

Default value:None
Supports wildcards:False
DontShow:False

Parameter sets

ByName
Position:0
Mandatory:True
Value from pipeline:False
Value from pipeline by property name:True
Value from remaining arguments:False

-PassThru

Returns an object representing the item with which you are working. By default, this cmdlet does not generate any output.

Parameter properties

Type:SwitchParameter
Default value:None
Supports wildcards:False
DontShow:False

Parameter sets

(All)
Position:Named
Mandatory:False
Value from pipeline:False
Value from pipeline by property name:False
Value from remaining arguments:False

-ThrottleLimit

Specifies the maximum number of concurrent operations that can be established to run the cmdlet. If this parameter is omitted or a value of 0 is entered, then Windows PowerShell® calculates an optimum throttle limit for the cmdlet based on the number of CIM cmdlets that are running on the computer. The throttle limit applies only to the current cmdlet, not to the session or to the computer.

Parameter properties

Type:Int32
Default value:None
Supports wildcards:False
DontShow:False

Parameter sets

(All)
Position:Named
Mandatory:False
Value from pipeline:False
Value from pipeline by property name:False
Value from remaining arguments:False

-WhatIf

Shows what would happen if the cmdlet runs. The cmdlet is not run.

Parameter properties

Type:SwitchParameter
Default value:False
Supports wildcards:False
DontShow:False
Aliases:wi

Parameter sets

(All)
Position:Named
Mandatory:False
Value from pipeline:False
Value from pipeline by property name:False
Value from remaining arguments:False

CommonParameters

This cmdlet supports the common parameters: -Debug, -ErrorAction, -ErrorVariable, -InformationAction, -InformationVariable, -OutBuffer, -OutVariable, -PipelineVariable, -ProgressAction, -Verbose, -WarningAction, and -WarningVariable. For more information, see about_CommonParameters.

Inputs

None

This cmdlet takes no input objects.

Outputs

None

By default, this cmdlet produces no output.